electronique:zigbee
Différences
Ci-dessous, les différences entre deux révisions de la page.
| Les deux révisions précédentesRévision précédenteProchaine révision | Révision précédente | ||
| electronique:zigbee [21/05/2026 12:32] – cyrille | electronique:zigbee [24/05/2026 12:03] (Version actuelle) – cyrille | ||
|---|---|---|---|
| Ligne 18: | Ligne 18: | ||
| * [[https:// | * [[https:// | ||
| * [[https:// | * [[https:// | ||
| + | |||
| + | cluster: 16 bits, attribut: 16 bits, value: variable selon ZCL. | ||
| + | |||
| + | value data type ZCL page 98. | ||
| + | |||
| + | Attribut Access (Acc) page 58 : Read: R, Write: W, Read/Write: RW, Read*Write: R*W, Report: P, Scene: S | ||
| ^ Cluster ^ Attr ^ Fonction ^ Commentaire ^ | ^ Cluster ^ Attr ^ Fonction ^ Commentaire ^ | ||
| Ligne 28: | Ligne 34: | ||
| | 0x0005 | | Scenes | for setting up and recalling a number of scenes for a device | | | 0x0005 | | Scenes | for setting up and recalling a number of scenes for a device | | ||
| | 0x0006 | | On/Off | état actuel on/off, état par défaut, durée de transition. | | | 0x0006 | | On/Off | état actuel on/off, état par défaut, durée de transition. | | ||
| - | | | 0000 | on/off | | | + | | | 0x0000 |
| | 0x0007 | | On/Off Switch Configuration | | | | 0x0007 | | On/Off Switch Configuration | | | ||
| | 0x0012 | | Multistate Input | | | | 0x0012 | | Multistate Input | | | ||
| Ligne 45: | Ligne 51: | ||
| ^ Security and Safety ^^^^ | ^ Security and Safety ^^^^ | ||
| | 0x0500 | | IAS Zone | | | | 0x0500 | | IAS Zone | | | ||
| - | | 0x0b04 | | Electrical Measurement | | | + | ^ Electrical Measurement ^^^^ |
| + | | 0x0b04 | | Electrical Measurement | (ZCL p338) | | ||
| + | | | 0x0000 | ||
| + | | | 0x0001 | DC Measurement | | | ||
| + | | | 0x0002 | DC Formatting | | | ||
| + | | | 0x0003 | AC (Non-phase Specific) Measurements | | | ||
| + | | | 0x0004 | AC (Non-phase Specific) Formatting | | | ||
| + | | | 0x0005 | AC (Single Phase or Phase A) Measurements | | | ||
| + | | | 0x0006 | AC Formatting | | | ||
| + | | | 0x0007 | DC Manufacturer Threshold Alarms | | | ||
| + | | | 0x0008 | AC Manufacturer Threshold Alarms | | | ||
| + | | | 0x0009 | AC Phase B Measurements | | | ||
| + | | | 0x000a | AC Phase C Measurements | | | ||
| + | | | 0x0505 | RMSVoltage | dec: 1285, uint16: 0x0000 – 0xffff | | ||
| + | | | 0x0508 | RMSCurrent | dec: 1288, uint16: 0x0000 – 0xffff | | ||
| + | | | 0x050b | ActivePower | dec: 1291, int16: -32768 – 32767 | | ||
| ^ Smart Energy ^^^^ | ^ Smart Energy ^^^^ | ||
| | 0x0700 | | Price | Commands and attributes for reporting price | | | 0x0700 | | Price | Commands and attributes for reporting price | | ||
| | 0x0701 | | Demand Response and Load Control | (ZCL p685) | | | 0x0701 | | Demand Response and Load Control | (ZCL p685) | | ||
| | 0x0702 | | Metering | (ZCL p714) | | | 0x0702 | | Metering | (ZCL p714) | | ||
| + | | | 0x0000 | Reading Information Set | | | ||
| + | | | 0x0001 | TOU Information Set | | | ||
| + | | | 0x0002 | Meter Status | | | ||
| + | | | 0x0003 | Formatting | | | ||
| + | | | 0x0004 | Historical Consumption | | | ||
| + | | | 0x0005 | Load Profile Configuration | | | ||
| + | | | 0x0006 | Supply Limit | | | ||
| + | | | 0x0007 | Block Information (Delivered) | | | ||
| + | | | 0x0008 | Alarms | | | ||
| + | | | 0x0009 | Block Information (Received) | | | ||
| + | | | 0x000A | Meter Billing Attribute Set | | | ||
| + | | | 0x000B | Supply Control Attribute Set | | | ||
| + | | | 0x000C | Alternative Historical Consumption | | | ||
| ^ Manufacturer specific cluster ^^^^ | ^ Manufacturer specific cluster ^^^^ | ||
| | 0xFC00 | | | 0xFC00 | | ||
electronique/zigbee.1779359520.txt.gz · Dernière modification : de cyrille